Id: | PE13.1
|
Autor: | Lázaro Cárdenas, Manuel Ernesto
|
Orientador: | Saldaña Juárez, Jacobo Ezequiel
|
Título: | La metoclopramida en perfusión miocárdica con 99MTC-MIBI y la calidad de imágenes en estudios isotópicos. Hospital Militar Central, junio 2014 - julio 2015^ies
Metoclopramide in myocardial perfusion with 99mTc-MIBI and quality of images in isotopic studies. Central Military Hospital, June 2014 - July 2015-
|
Fuente: | Lima; s.n; 2016. 36 tab.
|
Tese: | Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Licenciatura.
|
Resumen: | Objetivo: Determinar la influencia del uso de la metoclopramida durante la perfusión miocárdica con 99mTc-MIBI en la calidad de imágenes de estudios isotópicos realizados en el servicio de medicina nuclear del Hospital Militar Central durante junio del 2014 y julio del 2015. Material y métodos: estudio de tipo explicativo, retrospectivo y transversal. Para el estudio se trabajó con dos grupos: el primero 69 imágenes de perfusiones miocárdicas con uso de metoclopramida y el segundo 65 imágenes sin uso de metoclopramida con 99mTc-MIBI en el servicio de medicina nuclear del Hospital Militar Central durante los meses de junio del 2014 y julio del 2015. El programa estadístico utilizado fue SPSS v.21, utilizándose un análisis univariado de la calidad de imagen por medio de: valores mínimo, máximo, media y desviación estándar; para el análisis bivariado se comparó la calidad de imagen por medio de la prueba U de Mann-Whitney, usando previamente la prueba de Kolmogorov - Smirnov, trabajando con un nivel de significancia de 5 por ciento. Resultados: el 7.2 por ciento de los usuarios que usaron metoclopramida y el 18.5 por ciento que no usaron metoclopramida fueron de sexo femenino, el 92.8 por ciento de los usuarios que usaron metoclopramida y el 81.5 por ciento que no usaron metoclopramida fueron de sexo masculino. Al compararse la calidad de imagen entre los grupos de estudio en la condición de estrés para aquellos pacientes con uso de fármaco se encontró una diferencia muy significativa entre ambas (p=0,010) y al comparar la calidad de imagen entre los grupos de estudio en la condición de reposo para aquellos pacientes con esfuerzo físico, no se encontró diferencia significativa entre ambas (p=0,125). Cuando se comparó la calidad de imagen entre los grupos de estudio en la condición de estrés, se encontró una diferencia altamente significativa entre ambas (p<0,001), es decir, en los pacientes donde se empleó la metoclopramida se obtuvo una menor calidad de imagen...(AU)^iesObjective: to determine the influence of the use of metoclopramide during myocardial perfusion imaging with 99mTc-MIBI of images in the quality of isotopic studies in nuclear medicine service Central Military Hospital during June 2014 and July 2015. Methodology: explicative study, retrospective and transversal. For the study we worked with two groups: the first 69 images of myocardial perfusions with use of metoclopramide and the second 65 images without the use of metoclopramide with 99mTc-MIBI in the nuclear medicine service of the Central Military Hospital during the months of June 2014 and July 2015. The statistical program used was SPSS v.21, using a univariate analysis of image quality through: minimum, maximum, mean and standard deviation values; bivariate analysis for image quality was compared using the Mann- Whitney U test, previously using the Kolmogorov - Smirnov, working with a significance level of 5 per cent. Results: 7.2 per cent of users who used metoclopramide and 18.5 per cent who did not use metoclopramide were female, 92.8 per cent of users who used metoclopramide and 81.5 per cent who did not use metoclopramide were male. When comparing the picture quality between the study groups in the condition of stress for those patients using the drug was found a very significant difference between the two (p=0.010) and comparing the picture quality between the study groups in found rest condition for patients with physical effort, was found no significant difference between the two (p=0.125). When the image quality was compared between the study groups in the stress condition, a highly significant difference between the two was observed (p<0.001), ie in patients where metoclopramide is used a lower image quality was obtained was found than those who are not employed and comparing the picture quality between the study groups in the idle condition, a significant difference between the two (p=0.114) was not found. Conclusions: The metoclopramide...(AU)^ien.
|
Descriptores: | Metoclopramida/administración & dosificación Imagen de Perfusión Miocárdica Tecnecio Tc 99m Sestamibi Isquemia Miocárdica/diagnóstico - Estudios Retrospectivos Estudios Transversales
|
Límites: | Humanos Masculino Femenino Adulto Joven Adulto Mediana Edad Anciano
|
Medio Electrónico: | http://cybertesis.unmsm.edu.pe/bitstream/cybertesis/4948/1/Lazaro_cm.pdf / es
|
Localización: | PE13.1; T, WG 141.5.F9, L32, ej.1. 010000102015; PE13.1; T, WG 141.5.F9, L32, ej.2. 010000102016 |