português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
ECOCARDIOGRAFIA []
Referencias encontradas:
Mostrando:
1 .. 20   en el formato [Detallado]
página 1 de 3
ir para página          
  1 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Villanueva Muñoz, Omar Ludwing.
Título:Hallazgos ecocardiográficos en hipertensión arterial: Hospital Nacional Arzobispo Loayza, Lima, Perú^ies / Echocardiographic findings in arterial hypertension, Arzobispo Loayza Hospital, Lima, Peru
Fuente:Acta méd. peru;27(3):177-182, ago.-sept. 2010. ^btab, ^bgraf.
Resumen:Objetivo: Determinar los hallazgos ecocardiográficos en pacientes con HTA. Métodos: Estudio prospectivo, observacional, transversal, descriptivo. Se calculó un valor de n =81,6. Ingresaron al estudio 107 pacientes atendidos en los consultorios externos del Servicio de Cardiología - HNAL (del 10 de abril al 10 de mayo, 2010). La información fue recolectada en la ficha elaborada por el autor. Resultados: 72 (67,3%) mujeres y 35(32,7%) hombres fueron estudiados. La media de la edad fue de 68,26 ±10,2 años. Se analizaron: Geometría delVI y Disfunción Diastólica vs. Sexo del paciente y vs. control de la PA, así como la relación de la Geometría del VI vs. Disfunción Díastólica. Conclusiones: Existe una mayor prevalencia de HC en varones, y de RC y HE en mujeres. La DD tipo I fue más prevalente en pacientes con RC y HC. Estas relaciones no lograron significancia estadística. La relación entre mal control hipertensivo, la alteración de la geometría y DD no mostró significancia estadística. (AU)^iesObjectives: Determine the echocardiographics findings in patients with arterial hypertension.Methods: Prospective, observational and cross-sectional study. It was calculated a value of 81.6 subjects. 107 patients get into the studio; these patients were treated in outpatient service of Cardiology from the Arzobispo Loayza Hospital (Since April 10th to May 10th, 2010). Results: 72 (67.3%) women and 35(32.7%) men were considering in the studio. Average age was 68.26 ±10.2 years. The Geometry of the LV and Díastolic Dysfunction were analized vs. the blood pressure control and the sex of the patient. The GLV vs. DD, were compared too. Conclusions: There is a higher prevalence of CH in men, and of CR and EH in women. The DD tipe-I had a higher prevalence in patients with CR and CH. The findings were not statistically significant. The relationship among bad BP control, altered left ventricular geometry and DD showed no statistical value. (AU)^ien.
Descriptores:Ecocardiografía
Disfunción Ventricular
Hipertensión
Insuficiencia Cardíaca Diastólica
Epidemiología Descriptiva
 Estudios Transversales
 Estudios Prospectivos
 Estudios Observacionales
Límites:Humanos
Medio Electrónico:http://www.scielo.org.pe/pdf/amp/v27n3/a04v27n3.pdf / es
Localización:PE1.1

  2 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Arana Morales, Guillermo; Rojas Díaz, Pastor Ausberto; Jiménez, María; Soles, Regina.
Título:Ecocardiografía de stress con dobutamina como predictor de eventos coronarios agudos^ies / Dobutamine stress echocardiography as a predictor of acute coronary events
Fuente:Rev. peru. cardiol. (Lima);35(3):166-172, sept.-dic. 2009. ^bgraf.
Resumen:Objetivo: Evaluar la posibilidad de un estudio de ecocardiografía de stress con dobutamina puede predecir eventos coronarios agudos. Material y métodos: Realizaremos un estudio prospectivo en donde evaluamos a la totalidad de pacientes a quienes se les realizó de ecocardiografía de stress con dobutamina para descartar isquemia miocárdica, excluimos a aquellos pacientes que presentaron un síncrome coronario agudo previo al examen y en los que no se completó el seguimiento. Se realizó el seguimiento a los pacientes a través del sistema gestión hospitalaria para determinar si presentaron eventos (síndromes coronarios agudos o muerte por síndrome coronario agudo). Resultados: Se evaluaron 78 pacientes d elos cuales 08 fueron excluidos por la razón señalada en el párrafo anterior. La edad promerio fue 66.5; 43 (61.4 por ciento) paciente mujeres, todos tuvieron al menos un factor de riesgo cardiovascular. 09 pacientes son diabéticos (12.9 por ciento). Respecto a los resultados de la prueba de ecocardiografía de stress con dobutamina, 08 fueron positivas (11.4 por ciento); de estos 05 tuvieron trastorno de motilidad en un solo segmento, 01 en 2 segmentos y 02 en más de 3 segmentos. 04 pacientes presentaron eventos (síndrome coronario): 02 infarto de miocardio y 02 angina inestable. De los 62 pacientes con ecodobutamina negativa; solo 01 (1.61 por ciento) presentó evento coronario agudo; y de los 08 positivos, 03 presentaron eventos coronarios agudos (37.5 por ciento). La relación entre positividad de la prueba y la aparición de eventos coronarios agudos en el tiempo resultó significativa (Exacta de Fisher p = 0.04), además se encontró asociación entre aparición de eventos afectados en la prueba (p = 0.018) y con la afectación del territorios de la arteria descendente anterior (DA) (Exacta de Fisher p = 0.01). Tanto en hombres como en mujeres la prueba positiva se asoció a presencia de eventos. (AU)^ies.
Descriptores:Ecocardiografía de Estrés/efectos adversos
Síndrome Coronario Agudo
Estudios Prospectivos
 Valor Predictivo de las Pruebas
Límites:Humanos
Masculino
Femenino
Medio Electrónico:http://repebis.upch.edu.pe/articulos/rpc/v35n3/a3.pdf / es
Localización:PE1.1

  3 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Rosales Rosales, José.
Título:Aplicaciones clínicas de las nuevas tecnologías en ecocardiografía de estrés^ies / Clinical applications of new technologies in stress echo cardiography
Fuente:Rev. peru. cardiol. (Lima);36(1):29-43, ene.-abr. 2010. ^bilus, ^btab, ^bgraf.
Resumen:Objetivo: Exponer los aportes de las nuevas tecnologías en el diagnostico de enfermedad coronaria durante los estudios de eco estrés de esfuerzo o’ farmacológico aumentando de esta manera la sensibilidad y especificidad de este método hacia las lesiones de único vaso debido al cambio en objetivo de estudio orientado mas a encontrar alteraciones de la deformación miocárdica y disfunción diastólica Materiales y métodos: se estudiaron 40 pacientes con eco cardiógrafo vivid 7 con transductor m4s y 3v (tridimensional) Utilizándose tecnologías Doppler tisular y por Speckle tracking para estudiar: deformación miocárdica (strain), tasa de deformación miocárdica (strain rate) e índice de contracción post sistólica Además se utilizo 3D en tiempo real, 9 cortes, 3D Doppler tisular y 3D strain rate. Resultados: de los 40 pacientes, 36 con conocida o sospecha de enfermedad coronaria y 2 tenían Miocardiopatía hipertrófica y 2 valvulares, el 80 por ciento fueron Eco estrés por esfuerzo y 20 por ciento farmacológico. Conclusión: las nuevas tecnologías agregaron sensibilidad y especificidad a la ecocardiografía convencional, sin agregar tiempo ni a la adquisición ni al análisis, como concluyeron estudios internacionales previos. (AU)^ies.
Descriptores:Ecocardiografía de Estrés
Enfermedad Coronaria/diagnóstico
Desarrollo Tecnológico
Límites:Humanos
Masculino
Femenino
Mediana Edad
Anciano
Medio Electrónico:http://repebis.upch.edu.pe/articulos/rpc/v36n1/a5.pdf / es
Localización:PE1.1

  4 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Laura Lozada, Manuel Milmark.
Título:Experiencia inicial en el Perú con ecocardiograma tridimensional Clínica san Borja -205 casos^ies / Initial experience in Peru with three-dimensional echocardiography, Clinica San Borja -205 cases
Fuente:Rev. peru. cardiol. (Lima);35(1):11-23, ene.-abr. 2009. ^btab, ^bilus.
Resumen:Objetivo: Mostrar la experiencia personal inicial en el país del estudio de las lesiones cardiacas con el ecocardiograma tridimensional (3D) y la posibilidad que ofrece de mejorar el diagnóstico por la visualización de la morfología cardiaca con imágenes 3D en tiempo real y vistas de las válvulas desde los ventrículos o desde las aurículas y los septos desde el lado derecho o izquierdo a voluntad del operador. Material y métodos: Se estudiaron 205 casos que fueron diagnosticados por eco 2D seleccionándolos en grupos de acuerdo a patología. El estudio se realizó con un equipo Vivid 7 con transductor matricial para 3D en tiempo real. Se comparó los hallazgos del Ecocardiograma bidimensional (2D) con los del 3D obtenidos en forma simultánea, clasificándolos según el aporte del 3D. En todos los casos se estudió la fracción de eyección por el método multicorte. Los casos con imágenes sub óptimas fueron excluidos. Resultados: De 205 casos, 130 fueron varones y 75 mujeres. Las edades fueron de 8 meses a 75 años. La distribución de la patología fue: 58 Valvulares, 45 cardiopatías congénitas, 12 masas, 46 enfermedad coronaria, 24 miocardiopatías y otras patología 20. El 3D mostró datos adicionales en el 10 por ciento de los casos; mejoró la visualización de la lesión y/o agregó datos en el 30 por ciento y no fue contributorio en el resto de pacientes. El tiempo promedio por estudio con 3D fue 20 a 35 minutos. Conclusión: La 3D agregó nuevas y útiles vistas anatómicas especialmente en enfermedad de válvula mitral y tricúspide así como en cardiopatías congénitas, mejorando la visión anatómica pre quirúrgica. Alcanzó información anatómica comparable con 2D convencional en la mayoría de pacientes, pero el 3D le dio el aporte de volumen, sin requerir la “reconstrucción mental” que requiere el eco 2D. El método no resulto tedioso, ni consumió tanto tiempo como en los inicios en que la reconstrucción era offline. (AU)^iesObjective: To show anecdotal experience in the country of the study of cardiac lesions with threedimensional echocardiography (3D) and the possibility to improve the diagnosis by visualization of cardiac morphology with 3D images in real-time view of the valves from the ventricles or the atria, and septa from the right or left side of the operator at will. Material and methods: 205 cases were diagnosed using two-dimensional (2D) echo and were grouped based on pathology. The study was performed with a Vivid 7 device with a 3D real time matrix transducer. The findings of the 2D were compared simultaneously with those obtained with the 3D echocardiography and classified according to the contribution of the three dimensional echocardiography. In all cases, the ejection fraction was studied using the multislice method. Cases with sub optimal images were excluded. Results: Of 205 cases, 130 were male and 75 female. The age range was between 8 months and 75 years old. The distribution of the pathology was: 58 valves diseases, 45 congenital heart disease, 12 intracardiac masses, 46 coronary heart disease, 24 cardiomyopathies and 20 other pathologies. The 3D echocardiography showed additional data on 10 per cent of the cases and improved the visualization of the lesion and /or added data in 30 per cent of the cases. The 3D echocardiography did not provide any contribution to the rest of the patients. The average time per 3D study was 20 to 35 minutes. Conclusion: Three-Dimensional Echocardiography added new and useful anatomical views; especially inmitral and tricuspid valve disease, as well as in congenital heart disease, improving the anatomical vision presurgery. Three-Dimensional Echocardiography provided anatomical information comparable to the one of the conventional two-dimensional echocardiography in most patients. (AU)^ien.
Descriptores:Ecocardiografía Tridimensional
Lesiones Cardíacas
Perú
Límites:Humanos
Masculino
Femenino
Lactante
Preescolar
Niño
Adolescente
Adulto
Mediana Edad
Anciano
Medio Electrónico:http://repebis.upch.edu.pe/articulos/rpc/v35n1/a2.pdf / es
Localización:PE1.1

  5 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Hinostroza Castillo, Cecilia.
Título:Cortriatriatum en niños: una anomalía cardíaca congénita de difícil diagnóstico^ies / Cortriatriatum in children: a cardiac congenital anomaly of difficult diagnosis
Fuente:Rev. peru. cardiol. (Lima);30(2):97-100, mayo-ago. 2004. ^btab, ^bgraf.
Resumen:Introducción: El cortriatriatum Sinistrum es una anomalía cardíaca congénita de difícil diagnóstico. El presente es un estudio retrospectivo de pacientes pediátricos con diagnóstico cortriatriatum. Métodods: El grupo de estudios estuvo formado por 10 pacientes (edades comprendidas desde 1 día hasta 3 años)con diagnóstico de cortriatriatum registrados desde1995 hasta el 2002; en quienes se analizó el cuadro clínico,electrocardiograma, radiografía de tórax y ecocardiografía. Resultados: El grupo etario más frecuente fue el comprendidode 1 día a 6 meses. El cuadro clínico de presentación más frecuente (50 por ciento) fuede insuficiencia cardiaca congestiva asociado a bronconeumonía. En el ECG se encontró desviación del eje QRS a la derecha (90 por ciento), hipertrofia de cavidades derechas(80 por ciento), crecimiento auricular derecho (40 por ciento). Radiológicamente el 80 por ciento presentó cardiomegalia con congestión venosa pulmonar. El diagnóstico final fue establecido en base al ecocardiograma. En todos los pacientes el diagnóstico fue realizado con ecocardiograma, y dos pacientes .necesitaron de cateterismo para evaluar el drenaje venosopulmonar o coexistencias de otras anomalías. Conclusiones: Cortriatriatum es una anomalía cardiacacongénita que requiere cirugía temprana. El uso de ecocardiografía doppler color es el mejor método diagnóstico. Durante el examen ecocardiográfico debe prestarse especial atención al drenaje venoso pulmonar. (AU)^ies.
Descriptores:Cardiopatías Congénitas/diagnóstico
Cardiopatías Congénitas/ultrasonografía
Ecocardiografía de Doppler
Límites:Recién Nacido
Lactante
Humanos
Masculino
Femenino
Localización:PE1.1

  6 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Mendoza Paulini, Aurelio; Pariona Javier, Marcos Lorenzo; Rivara Ruiz, Gustavo.
Título:Comportamiento del Doppler tisular durante la ecocardiografía de estrés farmacológico con dobutamina^ies / Behavior of the Doppler tisular during the echocardiography of pharmacological stress with dobutamina
Fuente:Rev. peru. cardiol. (Lima);30(2):86-90, mayo-ago. 2004. ^btab, ^bgraf.
Resumen:Objetivo: Describir el comportamiento de las variables del Doppler tisular (DT), medidas a nivel del anillo mitral, en pacientes sin alteraciones de la motilidad segmentaria en reposo durante el estrés farmacológico con dobutamina. Material y Métodos: Se registraron prospectivamente 139 pacientes sin alteración de la motilidad segmentaria, el 54 por ciento de ellosvarones.La edad media fue de 65 ± 10 años. Las medidas incluyeron los valores tisulares de la onda de llenado rápido (Em), contracción auricular (Am),onda sistólica (Sm) y la relación Em/Am. Resultados: Se registraron 106 (76 por ciento) pacientes con diagnóstico negativo para isquemia y 33 (23 por ciento) con diagnóstico positivo para isquemia. Las diferencias entre no isquémicos e isquémicos fueron: Em lateral en reposo 11.6 mas menos 3.1 y 12 mas menos 3.8 (p=O.1207), Em lateral pico 14 mas menos ± 3.9 y 12.7 mas menos 4 (p=O.0206); Em septal en reposo 9.6 mas menos 2.1 y 9.1 mas menos 2.6 (p=O.4335); Em septal pico 12 mas menos 4.6 y 1O.7 mas menos 2.3 (p=O.0473). Sm lateral y septal en reposo y pico mostraron diferencias significativas desde el.inicioal igual que los valores de Am respectivamente, la diferencia se mantuvo con el pico máximo en el caso de Sm, más no así con los valores de Am. La relación F) A más negativa fue la tendencia que predominó en ambos grupos encontrándose una diferencia significativa sólo en la cara septal. El análisis multivariado determinó quelos valores de Em y Sm, son índices que pueden servir de marcadores para diferenciar a los pacientes no isquémicos de los isquémicos, en tanto la relación Em/Am es inespecífica para esta diferencia. Conclusión: Los valores Em y Sm parecen ser las variables más sensibles para distinguir a los pacientes isquémicos y no isquémicos y podrían ser utilizadas para el diagnóstico de isquemia durante la ecocardiografía de estrés con dobutamina. (AU)^ies.
Descriptores:Ecocardiografía de Doppler/utilización
Ecocardiografía de Estrés
Dobutamina/farmacología
Estudios Prospectivos
Límites:Mediana Edad
Anciano
Humanos
Masculino
Femenino
Localización:PE1.1

  7 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Rios Mauricio, Juan José; Romero Cano, Ricardo.
Título:Determinación de la presión de llenado ventricular izquierdo por dopler tisular en pacientes con disfunción cardiaca sistólica y diastólica^ies / Determination of the pressure of ventricular left filling for dopler tissue in patients with cardiac systolic dysfunction and diastolic
Fuente:Rev. peru. cardiol. (Lima);33(1):16-19, ene.-abr. 2007. ^btab.
Resumen:El presente trabajo describe los hallazgos ecocardiográficos en pacientes del Hospital Regional Docente de Trujillo y de la Consulta Privada en el periodo comprendido entre Enero a Diciembre 2006. Se evaluaron 20 pacientes con disfunción diastólica y 40 pacientes con disfunción sistólica, utilizando el estudio ecocardiográfico M-B doppler pulsado-tisular y se calculó la presión de llenado ventricular izquierdo. Los pacientes con disfunción sistólica tuvieron el índice de presión de llenado ventricular izquierdo incrementado significativamente (p < = 0,01) con respecto a los pacientes con disfunción diastólica. (AU)^iesThe present research shows echocardiographic findings in patients of the Teaching Regional Hospital from Trujillo and Private Practice, in the period from January to December 2006. It were studied 20 patients with diastolic dysfunction and 40 patietns with systolic dysfunction, using echocardiographic M-B pulse-tissue doppler imagen, and the left ventricular filling pressures were measured. Patients with systolic dysfunction had increased left ventricular filling pressure index (p < =0,01) compared to patients with diastolic dysfunction. (AU)^ien.
Descriptores:Disfunción Ventricular Izquierda
Presión Sanguínea
Insuficiencia Cardíaca Congestiva
Ecocardiografía de Doppler
Límites:Adulto
Mediana Edad
Anciano
Humanos
Masculino
Femenino
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v33_n1/pdf/a04.pdf / es
Localización:PE1.1

  8 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Revilla Alcocer, Héctor José.
Título:Comparación del índice de performance miocárdico por doppler pulsado de flujo y doppler pulsado tisular^ies / Comparison of the index of performance myocardial for doppler touched of flow and doppler touched tisular
Fuente:Rev. peru. cardiol. (Lima);33(1):15-15, ene.-abr. 2007. .
Descriptores:Ecocardiografía de Doppler de Pulso
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v33_n1/pdf/a03.pdf / es
Localización:PE1.1

  9 / 50
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Bastidas Tirado, Ronald Misolino; Pinto Concha, Javier E.
Título:Comparación del índice de performance miocárdico por doppler pulsado de flujo y doppler pulsado tisular^ies / Comparison of the index of performance myocardial for doppler touched of flow and doppler touched tisular
Fuente:Rev. peru. cardiol. (Lima);33(1):4-14, ene.-abr. 2007. ^bilus, ^btab, ^bgraf.
Resumen:OBJETIVO: Demostrar que el índice de performance miocárdico (IPM) obtenido por doppler pulsado tisular (DT) y doppler pulsado de flujo (DF) son métodos comparables. ANTECEDENTES: El IPM, también llamado índice de Tei, es una herramienta de inestimable utilidad para la evaluación ventricular sistólica y diastólica y es un indicador de mal pronóstico en varias enfermedades cardiovasculares cuando su valor es elevado. Clásicamente se mide mediante el DF mitral y del tracto de salida de VI. Recientemente se ha propuesto medir el índice de Tei mediante el DT con la ventaja de medir los intervalos en un solo ciclo cardiaco a diferencia del método clásico donde es necesario medir intervalos en diferentes ciclos por lo que puede alterarse con fluctuaciones de la frecuencia cardiaca. Sin embargo hay pocos trabajos que evalúan la correlación y concordancia entre ambos métodos que es el objetivo de este estudio MATERIALES Y METODOS: Se realiza un estudio prospectivo en pacientes adultos que acuden al laboratorio de cardiología para una evaluación ecocardiográfica midiendo el IPM por medio del DF y por medio del DT. En la comparación de los métodosse usa gráficos de Bland-Altman y el análisis de Passing-Bablok. RESULTADOS: Se estudiaron 80 pacientes con edad promedio de 60 años, 36 hombres y 44 mujeres. Al comparar las mediciones entre los dos métodos se encuentra que hay diferencia significativa en todas las mediciones con una p < 0.05. Así el intervalo “a” (intervalo entre el fin de la onda A y el inicio de la onda E del siguiente ciclo) medido por DT (453.38ms) es mayor que el medido por el método tradicional (432.82 ms), el intervalo “b” (intervalo entre el inicio y fin del flujo aortico) por DT (294.43 ms) es menor que el método clásico (300.77 ms). La suma del tiempo decontracción isovolumétrica mas el tiempo de relajación isovolumétrica es mayor medido por el DT (158.96 ms) que el DF (132.05 ms). El IPM es mayor por DT (0.56) que el medido por DF ... (AU)^iesOBJECTIVE: Our aim was to demonstrate that the myocardial performance index (IPM) obtained by tissue Doppler imaging (DT) and pulsed wave Doppler (DF) are comparable methods. BACKGROUND: The IPM, call also Tei index, is a tool of invaluable utility for the evaluation of the systolic and diastolic ventricular function and it is an indicator of poor prognostic in several cardiovascular illnesses when its value is high. Classically it is measured using the DF mitral and of the outflow tract of the left ventricle. Recently the Tei index is measured using the DT with the advantage of measuring the intervals in a single heart cycle contrary to the classic method where it is necessary to measure intervals in different cycles what can alter with fluctuations of the heart frequency. However there are few studies that evaluate the correlation and agreement between both methods that is our objective. MATERIALS AND METHODS: A prospective study is made in adult patients with echocardiography measuring the IPM using the DF and using the DT. In the comparison of the methods it is used graphics of Bland-bltman and the analysis of Passing-Bablok. RESULTS: Eighty patients were studied with age average 60 year-old, 36 men and 44 women. When it is compared the mensurations among the two methods a significant difference it exists in all the mensurations with p <0.05. This way the interval “a” (interval among the end of the A wave and the beginning of the E wave of the following cycle) measured by DT (453.38 ms) is greater than by the traditional method (432.82 ms), the interval “b” (interval between the beginning and end of the aortic flow) for DT (294.43 ms) it is smaller than the classic method (300.77 ms). The sum of the time of isovolumic contraction and the relaxation isovolumic by the DT (158.96 ms) is greater than using the DF (132.05 ms). The IPM for DT (0.56) is greater than by DF (0.45). The correlation between both methods are of 0.85. ... (AU)^ien.
Descriptores:Ecocardiografía de Doppler de Pulso
Estudios Prospectivos
Límites:Adulto
Mediana Edad
Anciano
Ancianos de 80 Años y Mas
Humanos
Masculino
Femenino
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v33_n1/pdf/a02.pdf / es
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Torres Cerpa, Claudio Euler; Alzamora Iriarte, Marco Antonio.
Título:Pericardiocentesis con guía ecocardiográfica en el Hospital Edgardo Rebagliati 1998-2006 (serie de casos)^ies / Pericardiocentesis with guide echocardiographic in the Hospital Edgardo Rebagliati 1998-2006 (series of cases)
Fuente:Rev. peru. cardiol. (Lima);33(2):79-86, mayo-ago. 2007. ^bgraf.
Resumen:Para evaluar la seguridad y eficacia de la pericardiocentesis con guía ecocardiográfica se estudió de manera prospectiva entre los años 1998-2006 45 pacientes mayores de 18 años que tenían indicación de pericardiocentesis, que resultaron frustras por vía subxifoidea y en espera de ser realizada en sala de operaciones; en 43 de ellos se realizó el procedimiento con éxito con una eficacia de 95.5 por ciento y una tasa de complicaciones menores de 13.6 por ciento (6 pacientes) 5 presentaron arritmia ventricular simple y un paciente presentó un pequeño hematoma. No requirieron tratamiento adicional y no se presentaron complicaciones mayores. Se demuestra que esta modalidad de pericardiocentesis eficaz y segura, luego su amplio uso nos permitiría evitar el drenaje quirúrgico subxifoideo y reducir costos. (AU)^iesTo evaluate the safety and efficacy of pericardiocentesis guided by two-dimensional echocardiography we make a prospective study between 1998-2006. In 45 patients older than 18 years old with pericardiocentesis need but not successful result by subxiphoid technique, and waiting subxiphoid surgical drainage in surgery room. Pericardiocentesis guided by two-dimensional echocardiography was successful in 43 patients, which meant a diagnostic efficacy was 95.5 per cent; the rate of minor complications were 13.6 per cent (6 patients) that included five simple ventricular arrhythmia and one small hematoma, none of them required additional treatment, and majorcomplication did not occurr. Pericardiocentesis guided by two-dimensional echocardiography technique is safety and effective, and should be used of routine. In this way costs and rate of surgery room occupation forpericardial drainage would be reduced. (AU)^ien.
Descriptores:Pericardiocentesis
Ecocardiografía
Estudios de Casos
 Estudios Prospectivos
Límites:Adulto
Mediana Edad
Anciano
Humanos
Masculino
Femenino
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v33_n2/pdf/a06.pdf / es
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Yánac Chávez, Pedro.
Título:Disincronia cardiaca valorada por doppler tisular en pacientes con cadiomiopatia dilatada^ies / Cardiac disincronia valued for doppler tisular in patients with cadiomyopathy expanded
Fuente:Rev. peru. cardiol. (Lima);34(2):111-112, mayo-ago. 2008. .
Descriptores:Cardiomiopatía Dilatada/ultrasonografía
Insuficiencia Cardíaca Congestiva/ultrasonografía
Ecocardiografía
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v34_n2/pdf/a04v34n2.pdf / es
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Chacón Díaz, Manuel Alberto; Godoy Palomino, Armando.
Título:Valoración ecocardiográfica de disincronía ventricular en pacientes con cardiomiopatía dilatada^ies / Valuation echocardiographic of dysinchoronia ventricular in patients with cardiomyopathy expanded
Fuente:Rev. peru. cardiol. (Lima);34(2):99-108, mayo-ago. 2008. ^btab, ^bgraf.
Resumen:Se evaluó la prevalencia de disincronía ventricular en pacientes con cardiomiopatía dilatada en programade rehabilitación cardiaca. METODOS: Estudio observacional, descriptivo, transversal y prospectivo donde se realizó mediciones ecocardiográficas yelectrocardiográficas en busca de disincronia intra y/o interventricular a los pacientes con cardiomiopatía dilatada, se realizó test ergométricos para relacionar la disincronía con la clase funcional. RESULTADOS: Se incluyeron 43 pacientes. En su mayoría varones (93 por ciento) con etiología isquémica. Se encontró disincronía intraventricular en 29 pacientes (67.4 por ciento) e interventricular en 14 (32.5 por ciento). El 58 por ciento de pacientes con QRS angosto y el 91 por ciento con QRS ancho tenían disincronía intraventricular. No se encontró relación entre la duración del QRS y la disincronía intraventricular. El QRS predijo disincronía con una sensibilidad del 37 por ciento y especificidad del 92 por ciento. La clase funcional empeoró con la presencia de disincronía. CONCLUSIONES: La duración normal del complejo QRS no es un parámetro adecuado para descartar disincronía intraventricular. La presencia de un ventrículo disincrónico empeora la capacidad funcional del paciente con cardiomiopatía dilatada. (AU)^iesWe evaluated the prevalence of ventricular dissynchrony in patients with dilated cardiomyopathy included in a cardiac rehabilitation program. METHODS: Was a descriptive, observational, transversal and prospective trial, we made ecocardiographycs and electrocardiographycs measures searching for intraventricular or interventricular dissynchrony inthose patients, there were also made ergometrics tests to correlate the dissynchrony with the functional class.RESULTS: A total of 43 patients were included, mostly men (93 per cent), with ischemic aetiology. Intraventriculardissynchrony was present in 29 patients (67.4 per cent) and interventricular dissynchrony in 14 (32.5 per cent). A 58 per cent of patients with narrow QRS complex and a 91 per cent with a wide one, had intraventricular dissynchrony. There was no relationship between the QRS complex duration and the presence of intraventricular dissynchrony. Thesensibility and specifity of QRS complex duration to predict dissynchrony was 37 per cent and 92 per cent respectively.The functional class worsened in patients with dissynchrony. CONCLUSION: The normal durationof the QRS complex is not a good parameter to rule out the presence of intraventricular dissynchrony. Adissynchronous ventricle worsens the functional class of the patient with dilated cardiomyopathy. (AU)^ien.
Descriptores:Cardiomiopatía Dilatada/ultrasonografía
Insuficiencia Cardíaca Congestiva/ultrasonografía
Ecocardiografía
Estudios Observacionales
 Epidemiología Descriptiva
 Estudios Transversales
 Estudios Prospectivos
Límites:Mediana Edad
Anciano
Humanos
Masculino
Femenino
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v34_n2/pdf/a03v34n2.pdf / es
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Horna Noriega, Manuel.
Título:Evolución de la ecocardiografía^ies / Echocardiography evolution
Fuente:Rev. peru. cardiol. (Lima);34(2):82-83, mayo-ago. 2008. .
Descriptores:Ecocardiografía/historia
Medio Electrónico:http://sisbib.unmsm.edu.pe/BVRevistas/cardiologia/v34_n2/pdf/a01v34n2.pdf / es
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Sánchez Hurtado, Evelyn; Gutiérrez Villafuerte, César Arturo.
Título:Evolución y letalidad por endocarditis infecciosa en pacientes atendidos en el Hospital Nacional Dos de Mayo^ies / Infectious endocarditis evolution and lethality in patients attended at Dos de Mayo National Hospital
Fuente:An. Fac. Med. (Perú);67(2):125-133, abr.-jun. 2006. ^bgraf, ^btab.
Resumen:Objetivo: Evaluar la evolución y letalidad de los pacientes portadores de endocarditis infecciosa, así como la presencia de complicaciones y la influencia de estas sobre la mortalidad. Diseño: Estudio longitudinal no concurrente. Lugar: Servicio de cardiología del Hospital 2 de Mayo, hospital universitario. Pacientes: Pacientes con diagnóstico de endocarditis infecciosa. Intervenciones: Se revisó las historias clínicas de los pacientes con diagnóstico de endocarditis infecciosa atendidos entre junio de 1999 y junio de 2005. Se evaluó los criterios clínicos, de laboratorio y ecocardiográficos (criterios de Duke) empleados en el diagnóstico. Para el análisis estadístico, se realizó el análisis descriptivo y comparativo con el empleo de las pruebas de Fisher y t de Student y la comparación de las curvas de Kaplan Meier, para evaluar la supervivencia a través de la prueba de rango logarítmico. Principales medidas de resultados: Evaluación de supervivencia: Complicaciones y mortalidad en pacientes en endocarditis infecciosa. Resultados: Se estudió 75 pacientes, la edad promedio fue 42,1±20,4 años, 66,7 por ciento del sexo masculino. El 93,3 por ciento tenía cardiopatía de base. La presentación clínica incluyó insuficiencia cardiaca congestiva (73,3 por ciento), encefalopatía (17,3 por ciento) y fenómenos embólicos (50,6 por ciento). Se evaluó la evolución de los parámetros de laboratorio, evidenciándose deterioro de la función renal. El ecocardiograma evidenció presencia ... (AU)^iesObjective: To evaluate infectious endocarditis evolution and lethality as well as complications and their influence on mortality. Design: Non-concurrent longitudinal study. Setting: Dos de Mayo Hospital Cardiology service, a teaching hospital. Patients: Patients with infectious endocarditis. Interventions: Clinical charts, laboratory and echocardiographic (Dukes criteria) studies of patients with infectious endocarditis attended between June 1999 and June 2005 were reviewed. Fisher and Sudent t tests were used for statistical analysis and Kaplan Meier curves comparison and logarithmic range test to evaluate survival. Main outcome measures: Infectious endocarditis complications and mortality. Results: Seventy-five patients were studied, mean age 42,1±20,4 years, 66,7 per cent males; 93,3 per cent presented cardiopathy. Clinical presentation included heart failure (73,3 per cent), encephalopathy (17,3 per cent), and embolic phenomena (50,6 per cent). Laboratory evolution showed worsening renal function. Echocardiography demonstrated presence of vegetations in 97,3 per cent and complications like valve breakage (8 per cent), valve abscesses (4 per cent); 14,7 per cent of patients had surgery. Mortality was 14,7 per cent, caused by renal and septic complications affecting patients' survival. Conclusions: Mortality in this group was 14,7 per cent. Survival was affected by the number of complications, mainly renal and septic complications. (AU)^ien.
Descriptores:Endocarditis/diagnóstico
Endocarditis/complicaciones
Evolución Clínica
Letalidad
Ecocardiografía
Estudios Longitudinales
Límites:Preescolar
Niño
Adolescente
Adulto
Mediana Edad
Anciano
Humanos
Masculino
Femenino
Medio Electrónico:http://www.scielo.org.pe/pdf/afm/v67n2/a05v67n2.pdf / es
Localización:PE1.1; PE13.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Vargas Galgani, Mario.
Título:La ecocardiografía en el diagnóstico de malformaciones congénitas cardiacas infrecuentes: una revisión de imágenes interesantes^ies / The echocardiography in the diagnosis of congenital heart malformations rare: a review of interesting images
Fuente:Rev. peru. cardiol. (Lima);28(1):126-134, ene.-abr. 2002. ^bilus, ^bgraf.
Resumen:Se presenta a manera de miatlas diferentes cardiopatías congénitas infrecuentes evaluadas por el autor en los últimos años. Se sugieren diferentes recomendaciones para la evaluación de estos casos infrecuentes. El uso del ultrasonido ha revolucionado el diagnóstico de las cardiopatías congénitas. Desde los años 80 en que el eco bidimensional se asoció a la técnica doppler, permitió brindar información anatómica, hemodinámica y psudoangiográfica (doppler color) convirtiéndose en un pilar para el diagnóstico incruento de la mayoría de cardiopatías congénitas. Asimismo permitió expandir la capacidad diagnóstica a ambientes en donde otras ténicas rara vez o nunca lograron ingresar como son las salas de cuidados neonatales, la evaluación de la corrección intraoperatoria de las cardiopatías congénitas y el diagnóstico intrauterino de las mismas (ecocardiograma fetal). El impacato fue de tal magnitud que reemplazó en muchos casos al cateterismo cardiaco en la toma de decisiones (considerado en los 80's como indispensable para el diagnóstico y la toma de decisiones en los pacientes con cardiopatía congénita), permitiendo la corrección quirúrgica de muchas cardiopatías sin estudios invasivos. En nuestro país, el primer trabajo de corrección quirúrgica de cardiopatías congénitas sin estudio invasivo previo fue presentado por el autor en 1989 (XII Congreso Peruano de Cardiología). Las malformaciones congénitas del corazón tienen una incidencia de 8 de cada 1000 nacidos vivos. Muchas de ellas se presentan raramente o muchas de ellas tienen variantes o asociaciones infrecuentes. Vamos a revisar a manera de miniatlas las imágenes ecocardiográficas de varios de estos casos. Cuando se considere apropiado, se mostraran esquemas y/o imágenes de otras técnicas del mismo caso. (AU) ^ies.
Descriptores:Cardiopatías Congénitas/diagnóstico
Ecocardiografía
Límites:Humanos
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Torres Cerpa, Claudio Euler.
Título:Evaluación de método ecocardiográfico para calcular presión diastólica final de ventriculo izquierdo en pacientes con enfermedad coronaria^ies / Echocardiographic assessment of methods for calculating end diastolic pressure of the left ventricle in patients with coronary disease
Fuente:Rev. peru. cardiol. (Lima);28(1):42-49, ene.-abr. 2002. ^btab, ^bgraf.
Resumen:Con la finalidad de evaluar la utilidad, exactitud y confiabilidad del método ecocardiográfico para estimar presión diastólica final de ventrículo izquierdo en pacientes con enfermedad coronaria con función sistólica normal y disminuida se estudiaron 92 pacientes, 61 con función sistólica normal y 31 con función sistólica disminuida. El método ecocardiográfico evaluado demostró ser útil y exacto en pacientes con enfermedad coronaria y función sistólica normal o disminuida y función diastólica normal, relajación anormal o pseudonormalización con un coeficiente de correlación 0.85 y un coeficiente de determinación de 0.73. El método ecocardiográfico evaluado demostró no ser útil ni exacto en pacientes con enfermedad coronaria y función sistólica normal o disminuida y función diastólica restrictiva pues no existe correlación. El método ecocardiográfico evaluado demostró ser confiable para detectar presiones diastólicas finales elevadas (15 mm Hg. a más) en pacientes con enfermedad coronaria y función sistólica normal o disminuida y función diastólica normal, relajación anormal o pseudonormalización con sensibilidad de 75 por ciento, especificidad 96.8 por ciento valor predictivo positivo 88.2 por ciento y valor predictivo negativo de 92.3 por ciento. El método ecocardiográfico evaluado no demostró ser confiable para detectar presiones diastólicas finales elevadas (15 mm Hg o más) en pacientes con enfermedad coronaria y función sistólica normal o disminuida y función diastólica tipo restrictiva pues no existe correlación. (AU)^ies.
Descriptores:Ecocardiografía/métodos
Coronariopatía
Límites:Humanos
Masculino
Femenino
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Dejo Bustíos, Hugo Arturo.
Título:Estudio ecocardiográfico de las vegetaciones en endocarditis infecciosa^ies / Echocardiographic study of vegetations in infectious endocarditis
Fuente:Acta med. peru;11(3):18-20, sept. 1984. ^bilus.
Resumen:En cuatro pacientes con diagnóstico clínico y bacteriológico de Endocarditis infecciosa, se realiza examen ecocardiográfico mod- M-. Tres pacientes presentan insuficiencia valvular aórtica aguda y uno, insuficiencia valvular mitral aguda. Se observa en todos los casos, imágenes ecocardiográficas correspondientes a vegetaciones yuxtavalvulares, que están localizadas solamente, en las válvulas que exhiben alteración funcional. (AU)^ies.
Descriptores:Endocarditis Bacteriana
Ecocardiografía
Límites:Adulto
Humanos
Masculino
Femenino
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Pariona Javier, Marcos Lorenzo; Moreno Martinez, Sergio Antonio; Lizaraso Soto, Frank Antonio Octavio; Rivara D., Julio.
Título:Ecocardiografía de estrés con dobutamina para la detección de isquemia y viabilidad miocardica^ies / Echocardiography of stree with dobutamina for the ischemia detection and viability myocardic
Fuente:Rev. peru. cardiol. (Lima);26(1):29-33, ene.-jun. 2000. ^btab.
Resumen:El presente trabajo describe nuestra experiencia en el uso de la ecocardiografía de estrés con dobutamina para la detección de isquemia y viabilidad miocárdica. Entre enero de 1995 y abril de 1999 se realizaron 78 ecocardiogramas de estrés con dobutamina en el Servicio de Cardiología del HNERM. Los resultados de la movilidad parietal del ventrículo izquierdo fueron reportados según una escala arbitraria y dividiendo al ventrículo izquierdo en 16 segmentos según las recomendaciones de la Sociedad Americana de Ecocardiografia. Se encontró viabilidad miocárdica en 36 pacientes de los cuales 13 fueron revascularizados, encontrándose mejoría post-operatoria en 9 casos (valor predictivo positivo: 69,2 por ciento), en 13 pacientes no se encontró viabilidad miocárdica, dos de ellos fueron revascularizados, no evidenciándose mejoría en ninguno (valor predictivo negativo: 100 por ciento). Se encontró respuesta isquémica en 13 casos, de los cuales 9 fueron sometidos a coronariografía, encontrándose enfermedad multivaso en 8 pacientes (sensibilidad: 100 por ciento) y no encontrándose lesiones significativas en un caso (especificidad: 88 por ciento). No se presentó ningún caso de muerte, síndrome coronario agudo o arritmia maligna. Nuestros resultados son similares a los descritos en la literatura para la detección de isquemia y viabilidad miocárdica y confirman el bajo nivel de complicaciones del examen. Debido a su bajo costo y a la información que provee condiseramos que su uso para el manejo de los pacientes con enfermedad coronaria debería ser extensivamente difundido. (AU)^ies.
Descriptores:Isquemia Miocárdica/diagnóstico
Isquemia Miocárdica/radiografía
Ecocardiografía
Dobutamina/administración & dosificación
Dobutamina/uso diagnóstico
Límites:Adulto
Mediana Edad
Anciano
Humanos
Masculino
Femenino
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Vargas Galgani, Mario.
Título:Ecocardiografía y viabilidad miocárdica^ies / Ecocardiografia and viability miocardica
Fuente:Angioplastía Perú;1(3):14-22, oct. 2000. ^bilus, ^btab, ^bgraf.
Resumen:Viabilidad significa capaz de vivir. La detección de músculo por infarto o en casos de insuficiencia cardiaca isquémica son los escenarios clínicos más importantes en los cuales la presencia o no de viabilidad va a modificar la actitud terapéutica. Existe viabilidad celular y mecánica. Quizás es más importante determinar la viabilidad mecánica, es decir la capacidad de que un segmento cardiaco recupere su contracción. Existe diferentes métodos para evaluar la viabilidad y el PET ha sido considerado como patrón. Todos tienen como meta la recuperación de la concentración (viabilidad mecánica). Los métodos más utilizados en la práctica clínica para evaluar la viabilidad son el SPECT con radiofármacos y el ECO con dobutamina. Los estudios comparativos muestran que el ECO con dobutamina es algo menos sensible pero mucho más específico que el SPECT, posiblemente porque evalúa la viabilidad mecánica y no la celular como si lo hace el SPECT. El eco con contraste en tiempo real bajo estimulación con dobutamina (actualmente en desarrollo) va a permitir evaluar la mortalidad y perfusión simultáneamente siendo muy promisorio en la detección de músculo viable. (AU)^ies.
Descriptores:Ecocardiografía/métodos
Dobutamina
Infarto del Miocardio/terapia
Supervivencia Tisular
Límites:Adolescente
Adulto
Mediana Edad
Anciano
Humanos
Masculino
Femenino
Estudio Comparativo
Localización:PE1.1

lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Parra Galván, José; Durand Velásquez, Julio; Munayco Martínez, Fernando; Peña Perret, Cecilia.
Título:Infarto miocárdico en niños a propósito de un caso^ies / Myocardial infarction children in a case
Fuente:Angioplastía Perú;1(2):72-74, may. 2000. ^bilus.
Descriptores:Infarto del Miocardio/diagnóstico
Ecocardiografía
Síndrome Mucocutáneo Linfonodular
Límites:Niño
Humanos
Masculino
Localización:PE1.1



página 1 de 3
ir para página          

Base de datos  lipecs : Formulario avanzado

   
Buscar:
en el campo:
 
1     
2   
3