português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
IMAGEN DE PERFUSION MIOCARDICA []
Referencias encontradas:
Mostrando:
1 .. 3   en el formato [Detallado]
página 1 de 1
  1 / 3
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Urquiaga Calderón, Juan Antonio.
Título:Punto de vista: Camino a la multimodalidad de imágenes. Perfusión miocárdica y score de calcio, ¿útil para el cardiólogo clínico?^ies / Viewpoint: Road to multimodality images. Myocardial perfusion and calcium score, useful for the clinical cardiologist?
Fuente:Rev. peru. cardiol. (Lima);37(1):3-6, ene.-abr. 2011. .
Descriptores:Imagen de Perfusión Miocárdica
Enfermedad Coronaria
Isquemia
Límites:Humanos
Medio Electrónico:http://repebis.upch.edu.pe/articulos/rpc/v37n1/a1.pdf / es
Localización:PE1.1

  2 / 3
lipecs
seleccionar
imprimir
Id:PE13.1
Autor:Lázaro Cárdenas, Manuel Ernesto
Orientador:Saldaña Juárez, Jacobo Ezequiel
Título:La metoclopramida en perfusión miocárdica con 99MTC-MIBI y la calidad de imágenes en estudios isotópicos. Hospital Militar Central, junio 2014 - julio 2015^ies Metoclopramide in myocardial perfusion with 99mTc-MIBI and quality of images in isotopic studies. Central Military Hospital, June 2014 - July 2015-
Fuente:Lima; s.n; 2016. 36 tab.
Tese:Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Licenciatura.
Resumen:Objetivo: Determinar la influencia del uso de la metoclopramida durante la perfusión miocárdica con 99mTc-MIBI en la calidad de imágenes de estudios isotópicos realizados en el servicio de medicina nuclear del Hospital Militar Central durante junio del 2014 y julio del 2015. Material y métodos: estudio de tipo explicativo, retrospectivo y transversal. Para el estudio se trabajó con dos grupos: el primero 69 imágenes de perfusiones miocárdicas con uso de metoclopramida y el segundo 65 imágenes sin uso de metoclopramida con 99mTc-MIBI en el servicio de medicina nuclear del Hospital Militar Central durante los meses de junio del 2014 y julio del 2015. El programa estadístico utilizado fue SPSS v.21, utilizándose un análisis univariado de la calidad de imagen por medio de: valores mínimo, máximo, media y desviación estándar; para el análisis bivariado se comparó la calidad de imagen por medio de la prueba U de Mann-Whitney, usando previamente la prueba de Kolmogorov - Smirnov, trabajando con un nivel de significancia de 5 por ciento. Resultados: el 7.2 por ciento de los usuarios que usaron metoclopramida y el 18.5 por ciento que no usaron metoclopramida fueron de sexo femenino, el 92.8 por ciento de los usuarios que usaron metoclopramida y el 81.5 por ciento que no usaron metoclopramida fueron de sexo masculino. Al compararse la calidad de imagen entre los grupos de estudio en la condición de estrés para aquellos pacientes con uso de fármaco se encontró una diferencia muy significativa entre ambas (p=0,010) y al comparar la calidad de imagen entre los grupos de estudio en la condición de reposo para aquellos pacientes con esfuerzo físico, no se encontró diferencia significativa entre ambas (p=0,125). Cuando se comparó la calidad de imagen entre los grupos de estudio en la condición de estrés, se encontró una diferencia altamente significativa entre ambas (p<0,001), es decir, en los pacientes donde se empleó la metoclopramida se obtuvo una menor calidad de imagen...(AU)^iesObjective: to determine the influence of the use of metoclopramide during myocardial perfusion imaging with 99mTc-MIBI of images in the quality of isotopic studies in nuclear medicine service Central Military Hospital during June 2014 and July 2015. Methodology: explicative study, retrospective and transversal. For the study we worked with two groups: the first 69 images of myocardial perfusions with use of metoclopramide and the second 65 images without the use of metoclopramide with 99mTc-MIBI in the nuclear medicine service of the Central Military Hospital during the months of June 2014 and July 2015. The statistical program used was SPSS v.21, using a univariate analysis of image quality through: minimum, maximum, mean and standard deviation values; bivariate analysis for image quality was compared using the Mann- Whitney U test, previously using the Kolmogorov - Smirnov, working with a significance level of 5 per cent. Results: 7.2 per cent of users who used metoclopramide and 18.5 per cent who did not use metoclopramide were female, 92.8 per cent of users who used metoclopramide and 81.5 per cent who did not use metoclopramide were male. When comparing the picture quality between the study groups in the condition of stress for those patients using the drug was found a very significant difference between the two (p=0.010) and comparing the picture quality between the study groups in found rest condition for patients with physical effort, was found no significant difference between the two (p=0.125). When the image quality was compared between the study groups in the stress condition, a highly significant difference between the two was observed (p<0.001), ie in patients where metoclopramide is used a lower image quality was obtained was found than those who are not employed and comparing the picture quality between the study groups in the idle condition, a significant difference between the two (p=0.114) was not found. Conclusions: The metoclopramide...(AU)^ien.
Descriptores:Metoclopramida/administración & dosificación
Imagen de Perfusión Miocárdica
Tecnecio Tc 99m Sestamibi
Isquemia Miocárdica/diagnóstico
Estudios Retrospectivos
 Estudios Transversales
Límites:Humanos
Masculino
Femenino
Adulto Joven
Adulto
Mediana Edad
Anciano
Medio Electrónico:http://cybertesis.unmsm.edu.pe/bitstream/cybertesis/4948/1/Lazaro_cm.pdf / es
Localización:PE13.1; T, WG 141.5.F9, L32, ej.1. 010000102015; PE13.1; T, WG 141.5.F9, L32, ej.2. 010000102016

  3 / 3
lipecs
seleccionar
imprimir
Id:PE13.1
Autor:Prado Cardenas, Mauricio
Orientador:Bernal Quispe, Luis Frank; Beltrán Ore, Elizabeth
Título:Visualización de la pared inferior y ápex cardiaco con la ingesta de agua fría en el estudio de Cardio SPECT^ies Viewing of the bottom wall and cardiac apex with the intake of cold water in the study of Cardio SPECT-
Fuente:Lima; s.n; 2016. 67 ilus, tab, graf.
Tese:Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Licenciatura.
Resumen:Se ha realizado un estudio de tipo observacional, método descriptivo - comparativo, prospectivo y de corte transversal. Para evaluar el uso de la ingesta de agua fría como método para eliminar el artefacto de superposición intestinal en el estudio de SPECT miocárdica. La población de 69 casos de la clínica San Gabriel del área de radiología por medicina nuclear que se realizaron un estudio de cardio SPECT en el periodo de abril a octubre del 2015. La muestras, se seleccionó de manera no probabilística, con la modalidad intencional o por conveniencia, constituida por 9 casos que presenta incidentalmente el artefacto de superposición. El resultado mostro un 13 por ciento de artefactos de superposición. El sexo femenino muestra la mayor frecuencia con un 66.7 por ciento. La edad media en mujeres es 56,5 años y la edad media en hombres es 55 años. El uso del agua fría mostro un valor de índice kappa de 0,750 y un test de Wilcoxon en cada observador con valores muy cercanos a 3 (visible). Lo cual representa una buena concordancia y un alto valor de significancia en la apreciación de la pared inferior del ápex cardiaco por los observadores post ingesta de agua fría. Conclusión: La ingesta de agua fría es efectiva en cuanto a la eliminación del artefacto de superposición intestinal en estudios de perfusión miocárdica. (AU)^iesThere has been an observational study, descriptive method - comparative, prospective and cross-sectional. To evaluate the use of cold water intake as a method for removing artifact intestinal overlap in the study of myocardial SPECT. The population of 69 cases of the San Gabriel area clinic radiology nuclear medicine SPECT study of cardio performed in the period from April to October 2015. The sample was selected non probabilistic with intentional conduct or for convenience, consisting of 9 cases that incidentally presents the overlap artifact. The result showed a 13 per cent overlap artifacts. The female shows more frequently with 66.7 per cent. The average age for women is 56.5 years and the average age for men is 55 years. The use of cold water showed a kappa value of 0.750 and Wilcoxon test for each observer with close to 3 (visible) values. Which is a good agreement and a high value of significance in the assessment of the bottom wall of the cardiac apex by post cold water intake observers. Conclusion: Cold water intake is effective in terms of removing the artifact intestinal overlap in myocardial perfusion. (AU)^ien.
Descriptores:Imagen de Perfusión Miocárdica
Cinetocardiografía
Tomografía Computarizada de Emisión de Fotón Único
Estudios Observacionales como Asunto
 Estudios Prospectivos
 Estudios Transversales
Límites:Humanos
Masculino
Femenino
Mediana Edad
Anciano
Anciano de 80 o más Años
Medio Electrónico:http://cybertesis.unmsm.edu.pe/bitstream/cybertesis/4850/1/Prado_cm.pdf / es
Localización:PE13.1; T, WN 203, P84, ej.1. 010000101572; PE13.1; T, WN 203, P84, ej.2. 010000101573



página 1 de 1

Base de datos  lipecs : Formulario avanzado

   
Buscar:
en el campo:
 
1     
2   
3