Id: | PE13.1
|
Autor: | Valdivia Huamán, Amy Kassushi
|
Orientador: | Salazar Salvatierra, Emma Felicia
|
Título: | Eficacia del monitoreo electrónico anteparto en el diagnóstico de sufrimiento fetal - Instituto Nacional Materno Perinatal - 2013^ies
Effectiveness of antepartum electronic monitoring in the diagnosis of fetal distress - National Institute Materno Perinatal - 2013-
|
Fuente: | Lima; s.n; 2014. 44 tab.
|
Tese: | Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Licenciatura.
|
Resumen: | Objetivo: Determinar la eficacia del monitoreo electrónico anteparto para el diagnóstico de sufrimiento fetal, basado en los resultados del Apgar y del líquido amniótico, en pacientes atendidas en el Instituto Nacional Materno Perinatal durante el período 2013. Metodología: Estudio de tipo observacional, con diseño analítico y retrospectivo, en el cual participaron 346 gestantes a quienes se realizó monitoreo electrónico fetal anteparto con y sin diagnóstico de sufrimiento fetal que acudieron a la Unidad de Medicina fetal del Instituto Nacional Materno Perinatal durante el año 2013. La información fue procesada mediante el programa SPSS v.21. Las variables cuantitativas se estimaron mediante medidas de tendencia central (media) y medidas de dispersión (desviación estándar). Para variables cualitativas se estimaron frecuencias absolutas y relativas (porcentajes). En el caso bivariado se utilizó pruebas no paramétricas como Chi-cuadrado. Resultados: Los hallazgos del monitoreo electrónico fetal fueron: línea de base normal (86.8 por ciento), variabilidad disminuida (15 por ciento), desaceleraciones tardías (5.8 por ciento) y desaceleraciones variables (3.3 por ciento), observándose desaceleraciones <50 por ciento en el 11.3 por ciento. Entre los resultados del parto: El 62.1 por ciento de las pacientes fue sometida a cesárea y el 37.9 por ciento culminó en parto vaginal, de los cuales el 19.9 por ciento tuvo líquido meconial fluido y en el 2.3 por ciento líquido meconial espeso. Se encontró un Apgar al minuto <4 en el 3.8 por ciento de los recién nacidos y entre 4-6 puntos en el 1.7 por ciento. El Apgar a los 5 minutos <4 se manifestó en un 1.2 por ciento y entre 4-6 puntos en un 1.7 por ciento. Los casos de sufrimiento fetal por monitoreo electrónico anteparto (MEF+) fueron diagnosticados en un 30.1 por ciento. Respecto al MEF positivo y los resultados neonatales, se observa relación entre el sufrimiento fetal diagnosticado por monitoreo electrónico...(AU)^iesObjective: To determinate the efficacy antepartum electronic monitoring for the diagnosis of fetal distress, based on the results of amniotic fluid Apgar and in patients treated at the Institute Nacional Materno Perinatal during the period 2013. Methodology: Observational study with analytical and retrospective design, in which 346 pregnant women was selected who participated in antepartum electronic fetal monitoring with and without a diagnosis of fetal distress that attended the Fetal Medicine Unit of the National Maternal Perinatal Institute in 2013. The data were processed using SPSS v.21 program Quantitative variables were estimated using measures of central tendency (mean) and measures of dispersion (standard deviation). For qualitative variables, absolute and relative frequencies (percentage) were estimated. A nonparametric test such as Chi-square test was used in the bivariate case. Results: The electronic fetal monitoring findings were: normal baseline (86.8 per cent), decreased variability (15 per cent), late decelerations (5.8 per cent) and variable decelerations (3.3 per cent), with decelerations <50 per cent in 11.3 per cent. Between birth outcomes: 62.1 per cent of patients were subjected to cesarean section and 37.9 per cent culminate in vaginal delivery, of which 19.9 per cent had liquid fluid and meconium 2.3 per cent, Liquid thick meconium. One minute Apgar <4 was found in 3.8 per cent of newborns and 4-6 points in the 1.7 per cent. The Apgar score at 5 minutes <4 was manifested by 1.2 per cent between 4-6 points and 1.7 per cent. The cases of antepartum fetal distress by electronic monitoring (EFM +) were diagnosed in 30.1 per cent. With regard to positive MEF and neonatal outcomes was observed relationship between fetal distress diagnosed by electronic fetal monitoring with minute Apgar (p<0.001) and Apgar score at 5 minutes (p=0.002), however there are no relationship significant between fetal distress diagnosed by electronic fetal...(AU)^ien.
|
Descriptores: | Sufrimiento Fetal/diagnóstico Monitoreo Fetal Puntaje de Apgar Líquido Amniótico - Estudio Observacional como Asunto Estudios Retrospectivos
|
Límites: | Humanos Masculino Femenino Niño Adolescente Adulto Joven Adulto Mediana Edad
|
Medio Electrónico: | http://cybertesis.unmsm.edu.pe/bitstream/cybertesis/3611/1/Valdivia_ha.pdf / es
|
Localización: | PE13.1; O, WQ, 209, V19, ej.1. 010000097198; PE13.1; O, WQ, 209, V19, ej.2. 010000097199 |