português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
MEDICINA NUCLEAR []
Referencias encontradas:
Mostrando:
1 .. 4   en el formato [Detallado]
página 1 de 1
  1 / 4
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Seminario Arce, Conrado G.
Título:Radiofármacos emisores de positrones: nuevos rumbos para la medicina nuclear^ies / Radiopharmacs emitting positrons: new courses for nuclear medicine
Fuente:Rev. serv. sanid. fuerzas polic;50(1):74-76, ene.-jun. 1989. ^atab.
Descriptores:Radioisótopos
Medicina Nuclear
Localización:PE1.1

  2 / 4
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Falcón Bornás, Saúl; Beretta Barreda, Mario.
Título:Técnicas computarizadas en medicina nuclear^ies / Computarized technics in nuclear medicine
Fuente:Diagnóstico (Perú);17(1):4-10, ene. 1986. ^ailus^btab.
Resumen:En este estudio preliminar de las aplicaciones de técnicas computarizadas en Medicina Nuclear, escogimos las aplicaciones en Cardiología y Nefrourología. El objetivo del trabajo fue introducir en el Centro de Biología y Medicina Nuclear del Instituto Peruano de Energía Nuclear (IPEN) estos métodos de diagnóstico, alcanzar su normalización, abriendo posibilidades de realizar las modificaciones técnicas necesarias. Hasta el momento de escribir este informe se han efectuado 90 estudios, 31 de ellos de corazón incluyendo los del primer pasaje y de equilibrio y en 59 estudios dinámicos renales (AU)^ies.
Descriptores:Sistemas de Computación
Medicina Nuclear
Diagnóstico por Computador/métodos
 Perú
Límites:Mediana Edad
Humanos
Localización:PE1.1

  3 / 4
lipecs
seleccionar
imprimir
Id:PE13.1
Autor:Valerio Rao, Andreé Ciannelli
Orientador:Tenio Obregón, Abelardo Néstor; Bernal Quispe, Luis Frank
Título:Calidad de imagen en la optimización de la actividad administrada en gammagrafía ósea MDP-Tc99m en la Clínica Jesús del Norte de Noviembre del 2011 a Mayo del 2012^ies Image quality in the optimization of the administered activity in bones cintigraphy MDP-Tc99m in the Clinic Jesus Norte in November 2011 to May 2012-
Fuente:Lima; s.n; 2012. 54 ilus, tab, graf.
Tese:Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Licenciatura.
Resumen:La base de la calidad de imagen es la capacidad del sistema de imagen para detectar diferencias de captación de un radiofármaco entre una zona de lesión y las zonas adyacentes. Por lo tanto, una imagen de alta calidad es aquella en que se puede visualizar la diferencia de captación para lograr un diagnóstico correcto. La exposición de los pacientes durante la gammagrafía es deliberada y no puede ser reducida indefinidamente sin perjuicio del examen para el cual ha sido realizada a través de un deterioro de la calidad de la imagen en la cámara gamma. Por otra parte, se requiere optimizar la protección del paciente, para prevenir la aparición de efectos estocásticos en los mismos. Una vía para lograr lo anterior es a partir de optimizar la actividad administrada al paciente. Con el objetivo de determinar el nivel de calidad de imagen que se obtiene al optimizar la actividad administrada en pacientes que se realizaron gammagrafía ósea MDP-Tc99m en pacientes de 18 a 65 años, se diseñó un estudio de tipo descriptivo retrospectivo en el que se evaluaron las imágenes digitales de 33 pacientes que acudieron al área de Medicina Nuclear de la Clínica Jesús del Norte entre los meses de noviembre del 2011 y mayo del presente año. El Médico Nuclear así como el Tecnólogo Médico se encargaron de verificar si los datos obtenidos de las historias clínicas así como las mediciones de la relación señal/fondo eran correctas, las cuales luego fueron analizadas mediante el prueba no paramétrica "Chi cuadrado" en el programa informático SPSS V15.0. Tenemos que el nivel actividad administrada en los pacientes Clínica Jesús del Norte en su mayoría se encuentra en un nivel normal con un 69.697 por ciento, seguido de un 24.242 por ciento que se encuentra en un nivel adecuado y finalmente un 6.0606 por ciento en un nivel alto de actividad. Pudiendo concluir que la optimización de actividad administrada a los pacientes en su mayoría se encuentra en el nivel normal por lo tanto las (...) (AU)^iesThe basis of the image quality is the ability of the imaging system to detect differences between a radiopharmaceutical uptake of lesion area and adjacent areas. Therefore, a high quality image is one in which the difference can be displayed to achieve uptake correct diagnosis. The exposure of patients during the scan is deliberate and can't be reduced indefinitely without prejudice to the consideration for which was conducted through a deterioration in the quality of the gamma camera image. Moreover, protection requires optimizing the patient, to prevent the occurrence of stochastic effects thereof. One way to achieve this is to optimize the activity from administered to the patient. In order to determine the level of image quality is obtained by optimizing the administered activity in patients who underwent Tc99m MDP-bones cintigraphy in patients 18 to 65 years, we designed a retrospective descriptive study which evaluated digital images of 33 patients who came to the area of Nuclear Medicine Clinic Jesus del Norte between the months of November 2011 and May this year. The nuclear physician and the medical technologist were responsible for verifying whether the data obtained from the medical records as well as measurements of the signal/background were correct, which were then analyzed by nonparametric test "Chi-squared" in the program SPSS V15.0. We have administered activity level in patients of Clinic Jesus del Norte is mostly a normal level with a 69,697 per cent, followed by a 24,242 per cent which is at an appropriate level and finally a 6.0606 per cent at a high level of activity. May conclude that the optimizing the administered activity to patients mainly in the level is normal hence the final images may be used for diagnostic purposes (AU)^ien.
Descriptores:Cintigrafía
Diagnóstico por Imagen
Medicina Nuclear
Estudios Retrospectivos
 Estudios Transversales
Límites:Humanos
Masculino
Femenino
Adulto
Mediana Edad
Anciano
Localización:PE13.1; T, WN, 203, V61, ej.1. 010000091150; PE13.1; T, WN, 203, V61, ej.2. 010000091151

  4 / 4
lipecs
seleccionar
imprimir
Id:PE13.1
Autor:Araujo Cachay, Luis Carlos
Título:Comparación de la eficacia de 3700 MBq con 5550 MBq de radioyodo para ablación del remanente tiroideo en pacientes con cáncer diferenciado de tiroides que presentan metástasis ganglionar locoregional^ies Comparison of the efficacy of 3700 MBq with 5550 MBq of radioiodine for ablation of the thyroid remnant in patients with differentiated thyroid cancer presenting locoregional ganglionic metastasis-
Fuente:Lima; s.n; 2015. 51 tab.
Tese:Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Doctor.
Resumen:Objetivo: Determinar la eficacia de dos dosis de radioyodo para la ablación del remanente tiroideo en pacientes con Cáncer Diferenciado de Tiroides que presentan metástasis ganglionar locoregional. Metodología: El estudio fue de diseño experimental del tipo muestreo aleatorio simple. La muestra estuvo conformada por 40 pacientes con el diagnóstico de Cáncer diferenciado de tiroides con evidencia de metástasis ganglionar locoregional. Los pacientes fueron inscritos y randomizados en dos grupos, el grupo experimental (3700 MBq I-131) y grupo control (5550 MBq I-131). En relación a nuestro estudio la medición de la eficacia fue un rastreo corporal total con I-131 negativo, porcentaje de captación a las 24 horas < 0,5 por ciento y tiroglobulina sérica < 2 ng/ml. Resultados: Cuando se definió el éxito la ablación, solamente con el rastreo corporal con 1-131 negativo, no se encontraron diferencias entre el grupo de estudio (100 por ciento, P=0.31) y el grupo control (94,4 por ciento, para un P>0.05). Cuando se consideró el rastreo corporal total con I-131 más el valor de corte de la tiroglobulina sérica <2 ng/ml, si hubo diferencia significativa en la tasa de éxito de la ablación entre el grupo de estudio y el grupo control (P=0,006). Conclusión: La eficacia de la ablación del remanente tiroideo usando dosis de 3700 MBq es similar al de 5550 MBq de radioyodo en pacientes con cáncer diferenciado de tiroides que presentan metástasis ganglionar locoregional. (AU)^iesObjective: To determine the efficacy of two doses of radioiodine for thyroid remnant ablation in patients with differentiated thyroid cancer presenting locoregional lymph node metastases. Methodology: The experimental study design was simple random sampling type. The sample consisted of 40 patients with a diagnosis of differentiated thyroid cancer with evidence of locoregional lymph node metastases. Patients were enrolled and randomized into two groups, the experimental group (3700 MBq I-131) and control group (5550 MBq I-131). In relation to our study measuring the effectiveness was a total body sean with I-131 negative percentage uptake at 24 hours < 0.5 per cent and serum thyroglobulin < 2 ng/ml. Results: When success was defined ablation, only with the body scintigraphy with I-131 negative, no differences between the study group (100 per cent, P=0.31) and the control group (94.4 per cent, for a P>0.05). When the whole body sean was considered to I-131 over the cutoff value of serum thyroglobulin < 2 ng/ml, if there was significant difference in the success rate of ablation between the study group and the control group (P=0.006). Conclusion: The effectiveness of remaining thyroid ablation using 3700 MBq dose is similar to 5550 MBq of radioactive iodine in patients with differentiated thyroid cancer lymph node metastasis presenting locoregional. (AU)^ien.
Descriptores:Neoplasias de la Tiroides/cirugía
Radioisótopos de Yodo
Cintigrafía
Periodo Postoperatorio
Medicina Nuclear
Epidemiología Experimental
Límites:Humanos
Masculino
Femenino
Adulto Joven
Adulto
Mediana Edad
Medio Electrónico:http://cybertesis.unmsm.edu.pe/bitstream/cybertesis/4203/1/Araujo_cl.pdf / es
Localización:PE13.1; MD, WN, 420, A66, ej.1. 010000098523; PE13.1; MD, WN, 420, A66, ej.2. 010000098524



página 1 de 1

Base de datos  lipecs : Formulario avanzado

   
Buscar:
en el campo:
 
1     
2   
3