português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
INDICE TOBILLO BRAQUIAL []
Referencias encontradas:
Mostrando:
1 .. 1   en el formato [Detallado]
página 1 de 1
  1 / 1
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Posadas Rioja, David Gayo; Pérez Muñante, Mónica; Sosa Valle, Héctor Jesús; Ticse Aguirre, Ray Willy.
Título:Variabilidad intra e inter examinador de la medición del índice tobillo braquial palpatorio utilizando un método estandarizado^ies / Inter and intra observer variability of the ankle-brachial index measured by palpation using a standardized method
Fuente:Rev. méd. hered;24(3):199-203, jul.-sept. 2013. ^bgraf, ^btab.
Resumen:Objetivos: Determinar la variabilidad del índice tobillo braquial palpatorio estandarizado (ITBp) inter e intra examinador y establecer la correlación de la palpación de los pulsos. Material y métodos: Se incluyeron 25 pacientes con factores de riesgo para desarrollar enfermedad arterial periférica. Cada examinador realizó 4 mediciones del ITBp así como la palpación de los pulsos. Para determinar la variabilidad intra examinador se usó la prueba de t Student y para la variabilidad inter examinador el análisis de multivariado de varianza. Se utilizó el índice Kappa para determinar la concordancia inter examinador en la palpación de de pulsos. Resultados: El 64% de la muestra fue de sexo masculino con edad promedio global de 59,28 ± 10,6. El 32% tenía diabetes mellitus y el 44% hipertensión arterial entre otros. En los pulsos braquial y pedio los índices (k) fueron 1 y 0, 8 respectivamente. Para el tibial posterior el fue 0,42-0,45 entre internos y médicos. Uno de los examinadores presentó un error estadísticamente significativo en la diferencia intra examinador y los más experimentados fueron los de menor diferencia en promedio. En las diferencias inter examinador el error no fue significativo. Conclusiones: Existe una buena correlación inter examinador para medir el ITBp, esto nos indica que el uso de un método estandarizado reduce dicha variabilidad y también el error. Asimismo, se evidencia que sí existe variabilidad intra examinador en el 25%, la cual es significativa. (AU)^iesObjectives: Determine inter and intra observer variability of the ankle-brachial index measured by palpation using a standardized method (ITBp), and to correlate it with pulse palpation. Methods: 25 patients with risk factors for developing peripheral arterial disease were included in the study. Each observer performed 4 measurements of the ITBp as well as palpation of the peripheral pulse. Intra observer variability was tested with the student’s t-test, and inter observer variability was tested with multivariate analysis of variance. Kappa statistics was used to determine the inter observer concordance of peripheral pulse palpation. Results: 64% of patients were male; mean age was 59.28 ± 10.6; 32% had diabetes mellitus, and 44% had hypertension. Kappa indexes for brachial and dorsalis pedis pulse were 1 and 0.8, respectively. Kappa indexes for posterior tibialis pulse measured by interns and attending physicians was 0.42 and 0.45, respectively. More experienced physicians had lesser overall differences in the intra observer measurements. No difference was observed in the inter observer measurements. Conclusions: Good inter observer correlation to measure ITBp was observed; indicating that using a standardized method reduces variability. A significant intra observer variability of 25% was observed. (AU)^ien.
Descriptores:Índice Tobillo Braquial
Enfermedad Arterial Periférica
Enfermedades Vasculares
Límites:Humanos
Masculino
Femenino
Adulto
Mediana Edad
Medio Electrónico:http://www.upch.edu.pe/vrinve/dugic/revistas/index.php/RMH/article/view/314/281 / es
Localización:PE1.1



página 1 de 1

Base de datos  lipecs : Formulario avanzado

   
Buscar:
en el campo:
 
1     
2   
3