português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
ESTENOSIS DE LA VALVULA AORTICA/MORTALIDAD []
Referencias encontradas:
Mostrando:
1 .. 1   en el formato [Detallado]
página 1 de 1
  1 / 1
lipecs
seleccionar
imprimir
Id:PE13.1
Autor:Vidal Martínez, David Alberto
Título:Características clínico quirúrgicas en pacientes mayores de 60 años post operados de reemplazo de válvula aórtica en el Hospital Nacional Dos de Mayo (2000-2010)^ies Surgical clinical characteristics in patients over 60 years post operated for aortic valve replacement at the National Hospital Dos de Mayo (2000-2010)-
Fuente:Lima; s.n; 2013. 45 tab, graf.
Tese:Presentada la Universidad Nacional Mayor de San Marcos. Facultad de Medicina para obtención del grado de Especialista.
Resumen:Objetivo: Describir las características clínico quirúrgicas en pacientes mayores de 60 años post operados de reemplazo de válvula aórtica. Materiales y Métodos: Se realizó un estudio descriptivo en pacientes intervenidos en el Hospital Dos de Mayo durante los meses entre enero 2000 y diciembre 2010. Introducción y objetivos: Los factores más importantes asociados a la mortalidad temprana en el recambio valvular aórtico del anciano son controvertidos. Realizamos un análisis de riesgo en estos pacientes. Pacientes y método: Se realizó un análisis uni y multivariante de los principales factores asociados a la mortalidad hospitalaria en 38 pacientes mayores de 60 años intervenidos de recambio valvular aórtico, entre enero 2000 y diciembre 2010 y el poder discriminante del modelo predictivo se evaluó mediante curvas ROC. Resultados: Los factores relacionados en el preoperatorio con mayor mortalidad en el análisis univariante fueron: Euroscore: riesgo medio (3-5) (p<0,002528), Cineangiografia con lesiones (p<0,000024), Dislipidemia (p<0,004691), diabetes mellitus (p<0,004279), Hipertensión arterial (p<0,025431), Fibrilación auricular (p<0,000146), y en las complicaciones postoperatorias son: bajo gasto cardiaco (p<0,000962), reoperación por sangrado (p<0,000962), ventilación mecánica >de 24 horas (p<0,098174), Fibrilación auricular (p<0,024698), Insuficiencia renal aguda (p<0,000962), Falla cardiaca congestiva (p<0,000921), complicaciones pulmonares (p<0,025643). La mortalidad estimada por el modelo predictivo fue del 2,19 por ciento, y superior a la calculada mediante el EuroSCORE a la mortalidad observada (7,69 por ciento) (con área bajo la curva ROC de 0,719). Conclusiones: Los factores asociados a una mayor mortalidad en el recambio valvular aórtico en pacientes ancianos son en el preoperatorio: el Euroscore medio, cineangiografia con lesiones, dislipidemia, diabetes mellitus, hipertensión arterial, fibrilación auricular, la existencia de complicaciones en el...(AU)^iesObjective: To describe the clinical surgical patients over 60 years post surgery for aortic valve replacement. Materials and Methods: A descriptive study of patients treated in the Hospital Dos de Mayo during the months between January 2000 and December 2010. Patients and methods: We performed univariate and multivariate analysis of the main factors associated with hospital mortality in 38 patients older than 60 years who underwent aortic valve replacement between January 2000 and December 2010 and the discriminating power of the predictive model was assessed using ROC curves. Results: Factors associated with increased mortality in the univariate analysis were: Euroscore: medium risk (3-5) (p<0.002528), cineangiography lesions (p<0.000024), dyslipidemia (p<0.004691), diabetes mellitus (p<0.004279), hypertension (p<0.025431), atrial fibrillation (p<0.000146), low cardiac output (p<0.000962), reoperation for bleeding (p<0.000962), mechanical ventilation > 24 hours (p<0.098174), atrial fibrillation (p<0.024698), acute renal failure (p<0.000962), congestive heart failure (p<0.000921), pulmonary complications (p<0.025643). Estimated mortality predictive model was 2.19 per cent, and higher than that ca1culated by EuroSCORE for mortality (7.69 per cent) (area under the ROC curve of 0.719). Conclusions: Factors associated with increased mortality in aortic valve replacement in elderly patients in the preoperative period are: the mean EuroSCORE, cineangiography with injuries, dyslipidemia, diabetes mellitus, hypertension, atrial fibrillation, the presence of postoperative complications such as: low cardiac output, reoperation for bleeding, mechanical ventilation> 24 hours, atrial fibrillation, congestive heart failure, acute renal failure, pulmonary complications. The predictive model based on the EuroSCORE has high discriminative power in our patients. Sex, prosthesis size and pump time have no direct influence on mortality. (AU)^ien.
Descriptores:Estenosis de la Válvula Aórtica/mortalidad
Estenosis de la Válvula Aórtica/cirugía
Periodo Preoperatorio
Estudios Retrospectivos
 Estudios Transversales
Límites:Humanos
Masculino
Femenino
Mediana Edad
Anciano
Anciano de 80 o más Años
Localización:PE13.1; ME, WG, 169, V63, ej.1. 010000093264; PE13.1; ME, WG, 169, V63, ej.2. 010000093265



página 1 de 1

Base de datos  lipecs : Formulario avanzado

   
Buscar:
en el campo:
 
1     
2   
3