português | english | français

logo

Búsqueda en bases de datos

Base de datos:
lipecs
Buscar:
ELASTOMEROS DE SILICONA []
Referencias encontradas:
Mostrando:
1 .. 2   en el formato [Detallado]
página 1 de 1
  1 / 2
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Galarreta Pinto, Pamela Haydeé; Kobayashi Shinya, Arturo.
Título:Estudio comparativo de la exactitud dimensional de tres materiales de impresión elastoméricos utilizados con y sin aplicación de adhesivos en prótesis fija^ies / A comparative study of the dimensional accuracy of three clastomeric impression materials used with and without application of adhesives in fixed prosthodontic
Fuente:Rev. estomatol. Hered;17(1):5-10, ene.-jun. 2007. ^bilus, ^btab.
Resumen:El propósito de este estudio fue comparar la exactitud dimensional de tres materiales de impresión con y sin aplicación de adhesivo. Los materiales utilizados fueron: silicona de condensación Oranwash L, Zetaplus (Zhermack), silicona de adición Elite H-D (Zhermack®) y poliéter Impregum™ Soft (3M ESPE). Se confeccionó un modelo maestro de acero inoxidable, el cual simulaba una hemi- arcada con preparaciones para prótesis fija. Por cada material se realizaron 20 impresiones, a 10 se les aplicó adhesivo a la cubeta. Se tomaron siete medidas a los modelos de yeso obtenidos de éstas impresiones mediante una máquina de medición por coordenadas Beyond 700 /900 Mitutoyo Corporation®, para ser comparadas con las medidas del modelo maestro. Se encontraron diferencias estadísticamente significativas con y sin aplicación de adhesivo para la silicona de condensación en la medida de la distancia bucolingual del pilar 1 (M7) y para la silicona de adición en la medida entre pilares (M6), mientras que para el poliéter no se encontraron diferencias significativas. Para todos los materiales de impresión se encontraron diferencias significativas con y sin aplicación de adhesivo y el modelo maestro, sin embargo con aplicación de adhesivo se encontró resultados más exactos. Con la silicona de adición se obtuvieron modelos más exactos tanto con como sin aplicación de adhesivo. (AU)^iesThe purpose of this study was to compare the dimensional accuracy of three impression materials with and without application of adhesives. The materials used were: condensation silicone Oranwash L, Zetaplus (Zhermack®), addition silicone Elite H-D (Zhermack®) and Polyether Impregum™ Soft (3M ESPE). A master model, was made of stainless steel, which simulated one hemi-arch with preparations for fixed prosthesis. For each material, 20 impressions were made ,in which 10 of them had adhesive over the tray impression and to the other 10 had no adhesive applied. Seven measures were taken :M1, M2, M3, M4, M5, M6 y M7, of the stone cast and were evaluated by means of a machine of measurement that coordinates, Beyond 700 /900 Mitutoyo Corporation®, to compared them with the measures of a master model. Student's t - test was used to compare the measures with and without application of adhesive, and between the stone casts and the master model. Analysis of Variation (Tukey) was used to compare between impression materials. Significant differences were found between the ones that had been added and those without the application of adhesive, for condensation silicone in the M7 measurement and for additional silicone in the M6 measurement; whereas polyether had no significant difference. Significant differences were found between all the materials with and without adhesive application and the master model, however the ones with the adhesive application result more accurate. The addition silicone was the material that showed more accurate results with and without adhesive application. (AU)^ien.
Descriptores:Materiales de Impresión Dental
Elastómeros de Silicona
Límites:Estudio Comparativo
Medio Electrónico:http://www.upch.edu.pe/faest/publica/2007/vol17_n1/vol17_n1_07_art1.pdf / es
Localización:PE1.1

  2 / 2
lipecs
seleccionar
imprimir
Id:PE1.1
Autor:Amorrortu Pereiro, Francisco Javier.
Título:Estabilidad dimensional de los materiales de impresión a base de elastómeros^ies / Dimensional stability of the materials of impression based on eslatomers
Fuente:Carta odonto;1(1):7-10, ene.-mar. 1982. ^btab, ^bgraf.
Resumen:Se llevó a cabo un trabajo de investigación, para determinar la estabilidad dimensional de materiales representativos de una gama de elastómeros. Se comparó el comportamiento de las nuevas siliconas tipo II (reacción química por adición) con las siliconas tipo I (reacción química por condensación), polisulfuros activados por dioxidos de plomo y poliéteres. Los resultados mostraron que todos los materiales de impresión a base de elastómeros, sufrieron algún tipo de cambio dimensional, ya sea durante la polimeración, o luego de ser retirados de un modelo matriz sin ángulos retentivos, y/o durante su almacenamiento. (AU)^ies.
Descriptores:Elastómeros de Silicona
Materiales de Impresión Dental
Técnica de Impresión Dental
Localización:PE1.1